Dhaka, Bangladesh
![]() |
Image courtesy of Volumezero |
Client : Volumezero Ltd |
Located in the Gulshan district of Dhaka, the office headquarters for Shahjalal Bank will be approximately 13,300m2 comprising a 13 storey tower above 3 basement floors.
Gulshan is a mixed residential and commercial area, and is also the location of many international government building including the Royal Thai Embassy, Embassy of the United States of America and the Australian High Commission.
The air conditioning system utilises high efficiency water cooled screw chillers with variable speed compressors. These operate on environmentally friendly HFC refrigerant and a refrigerant leak detection system is provided to allow rapid detection and rectification of any leak before the entire charge is lost to the atmosphere.
Variable Speed Drive (VSD) motors are provided on chilled water pumps to allow them to operate efficiently. Basement ventilation fans are provided with variable speed drives controlled by carbon monoxide sensors.
Precooled and dehumidified fresh air is provided to each floor by packaged air handling units.
As per the latest Bangladesh building code, 97m2 mono-crystalline photovoltaic cells (PV) cells will be installed on the building to provide approximately 5% of the total lighting load in the building. This will offset and reduce the electricity drawn from the grid.
The main power network is unreliable so diesel engine generators will be installed with the capacity to provide 100% standby power to the site for 8 hours.
Energy efficient T5 fluorescent lighting was selected for the building.
The building is fully sprinkler protected and includes pressurisation systems for the fire exit stairs and the fireman lift lobby.
Roof rainwater is collected and treated for use in irrigation on site.
..........................................................................................................................
About us
Our Story
Our Philosophy
Project Collaboration Philosophy
Delivery Strategy
Our Team
Service
Civil and Structural
Air conditioning and Ventilation
Electrical and Communications
Fire Protection
Plumbing and Hydraulics
Vertical Transportation Services
Sustainable Design Services
Building Information Modelling : BIM
Project
Showcase Our Work
List of Project
EEC LINCOLNE SCOTT CO.,LTD.
42 EEC Academy 2 Building, Soi Ram Inthra 97, Khan Na Yao, Khan Na Yao District, Bangkok 10230 Thailand.
Google Earth / Map
Tel : +66 2130 4599
Fax : +66 2130 4594
[email protected]